Table of Contents

Advertisement

Manual mode
P1-13
SI1
0
1
No function
2
Stop for edge control
3
No function
4
Stop for edge or signal control
Manual mode
P1-13
SI1
0
1
No function
2
No function
3
No function
4
Stop in FWD mode for edge or
signal control

5.7.5 Phase change

Parameter P1-13
Table 24:
Signal detection for RAMO5-D... direct starter
SI2
No function
Stop for edge control
No function
No function
Table 25:
Signal detection for RAMO5-W... reversing starter
SI2
No function
No function
No function
Stop in REV mode for edge or
signal control
Parameter P6-08 changes the rotating field at the output of RAMO5-W...
from FWD to REV. The control logic and the LED indicators remain in the
FWD function.
For RAMO5-W... the P6-08 parameter setting should be chan-
ged by competent users according to the instructions in the
manual.
For RAMO5-D..., parameter P6-08 has no function.
Parameter
Designation
P6-08
Change Phases
equence Motor
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Auto mode
SI1
No function
Stop for edge control
Stop for edge control
Stop for edge control
Auto mode
SI1
No function
Stop for edge control
Stop in FWD mode with edge
control
Stop in FWD mode for edge or
signal control
Description
Changes the sequence of the output
phases.
This prevents two phases of the motor
cable from having to be swapped in
case the motor runs in the wrong direc-
tion.
0: U – V – W (clockwise rotating field)
1: U – W – V (counterclockwise rota-
ting field)
5 RAMO5 motor starter
5.7 Configure specialist settings
SI2
No function
Stop for edge control
No function
No function
SI2
No function
No function
Stop in REV mode with edge
control
Stop in REV mode for edge or
signal control
Unit
Min
0
Max
DS
1
0
133