Specific Technical Data - Eaton Rapid Link 5 Manual

Table of Contents

Advertisement

6 RASP5 speed controller

6.4 Specific technical data

6.4 Specific technical data
Rated current (I
)
e
Overload current for 60 s every
600 s at 40 °C
Startup current for 2 s
every 20 s at 40 °C
Apparent power at 400 V rated
operation
Assigned motor power at 440 V,
60 Hz
Setting range
current limitation (P1-08)
Power supply side (primary side)
Number of phases
Rated voltage
Input current
Braking
Braking value
Switch-on threshold for the
braking transistor
138
The following tables show the technical data of the RASP5 speed controller
in the individual power classes with the assigned motor power.
The motor power allocation is based on the rated operational
current.
The motor power indicates the respective active power output
to the drive shaft of a normal, four pole, internally or externally
ventilated three-phase asynchronous motor with 1500 rpm
(at 50 Hz) and 1800 rpm (at 60 Hz).
Symbol
Unit
I
A
e
I
A
L
I
A
L
S
kVA
P
kW
P
HP
l
A
2
U
V
LN
I
A
LN
I/I
%
e
U
V DC
DC
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
RASP5-2...
RASP5-4...
2.4
4.3
3.6
6.5
4.8
8.6
1.84
3.27
0.75
1.5
1
2
0.2 - 2.4
0.4 - 4.3
3
3
380 V - 15 % - 480 V + 10 %, 50/60 Hz
(380 - 480 V ±0 %, 45 - 66 Hz ±0 %)
2.5
4.1
≦ 30
≦ 30
765
765
RASP5-5...
RASP5-8...
5.6
8.5
8.4
12.75
11.2
17
4.24
6.49
2.2
4
3
5
0.5 - 5.6
0.8 - 8.5
3
3
5.3
7.8
≦ 30
≦ 30
765
765

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid link ramo5Rapid link rasp5

Table of Contents