8.3.4 Parameter group 3 (Mechanical brake and digital inputs)

Parameter
Designation
P3-04
Brake Release Delay
P3-05
Brake Apply Delay
P3-06
SEN I1 Logic
P3-07
SEN I2 Logic
P3-08
SEN I3 Logic
P3-09
SEN I4 Logic
172
Table 37:
Parameter group 3 (Digital inputs/outputs)
Description
Determines the time before the mechanical brake is
released.
Determines the time between the signal to close the brake
and disabling of the drive.
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
0: normally open
1: normally closed
Note:
Change only after POWER ON / OFF active
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Unit
Min
Max
s
0
2.50
s
0
25.0
0
0
1
0
1
DS
0
0
0
0