216
The control section of the RASP5 speed controller (M12 input 24 V) can be
supplied with an external voltage of 24 V DC via an external power supply.
PWR
FLT
MS
NS
P1
P1 S
SEN I1/I3
I1
P1 A
P2
P2 S
I3
ACT Q1/2
Q1
P2 A
24V
Q2
SEN I2/I4
I2
I4
Figure 124:
M12 input 24 V
2
3
4
+24 V DC
0 V
100 mA
External Power
Supply
Figure 125:
External 24-V DC control voltage
The external control voltage (+24 V DC) must be able to handle
a load of at least 100 mA.
The residual ripple of this external control voltage must be less
than ±5 % ΔU
If the power is supplied by an external power supply unit, the control board
of the Rapid Link 5 module and the RJ45 interface will be active.
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
1
Not used
2
Not used
3
0 V
1
4
+24 V DC
/U
.
a
a