MCO 305 Design Guide
Software Reference
Command Overview
All commands are described in a general overview in groups and subsequent alphabetically ordered, in
detail and complemented with short examples.
Initialization Commands
Commands to initialize the axes and MCO 305 start up and define the zero point(s). (Group INI)
Command
Description
DEFMORIGIN
sets the current master position as the zero
point for the master
DEF ORIGIN
sets the actual position as zero point
DELETE ARRAYS deletes all arrays in the RAM
ERRCLR
clears error
HOME
moves to machine zero point
INDEX
moves to next index position
MOTOR OFF
turns off motor control
MOTOR ON
turns on motor control
RST ORIGIN
resets temporary zero point
SETMORIGIN
set the current position as the zero point for
the master
SET ORIGIN
sets temporary zero point
SAVE ARRAYS
save arrays in the EEPROM
SAVE AXPARS
save current axis parameters in the EEPROM
SAVE GLBPARS
save current global parameters in the EEPROM SAVE GLBPARS
SAVEPROM
saves memory in EEPROM
SWAPMENC
swap master and slave encoder internally
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Syntax
Parameter
DEFMORIGIN
DEF ORIGIN
DELETE ARRAYS
ERRCLR
HOME
INDEX
MOTOR OFF
MOTOR ON
RST ORIGIN
SETMORIGIN value value = absolute position
SET ORIGIN p
p = absolute position
SAVE ARRAYS
SAVE AXPARS
SAVEPROM
SWAPMENC s
s = condition ON / OFF
89