Danfoss MCO 305 Design Manual page 177

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Parameter Reference
FC 300, MCO 305, and Application Parameters
Basically there are these main parameter types: FC 300 parameters, MCO 305 parameters, and application
parameters (group 19-**):
– FC 300 and MCO 305 Parameters
The parameters concerning the Frequency Converter are described in FC 300 Design Guide. The follo-
wing section describes all the parameters which are necessary or helpful using the MCO 305.
Default Setting and Reset
All parameters has a default setting ex factory which can be reset by manual initialization of the FC 300
or by means of the setup copy function (see in FC 300 operating instruction for further details).
The parameters can also be reset to default settings in menu Controller
Complete . Deleting the entire memory in menu Controller
parameters to default setting as well.
– Application Parameters
The application parameters 19-00 to 19-99 are defined in a APOSS program using the command
LINKGPAR and will be displayed in the LCP.
The parameters 19-90 to 19-99 are read only parameters which can be used for data read out on the
LCP in display line 1 or 2. You can select which parameters are displayed at which position on the FC 300
by means of par. 0-2* LCP Display.
Parameter Access
There are three methods to access parameters:
LCP
PC Software MCT 10
Field bus
default setting
[ ]
value for use in communication via serial communication port
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Reset
Parameters or
Memory
Delete EEPROM will reset the
177