Download Print this page

Danfoss MCO 305 Design Manual page 62

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Controller Menu
With these functions you can manage your
programs: You can save or delete the programs in
the option EEPROM and can mark a program for
Autostart.
Programs
Click on Controller
Programs and the dialog shows all the connected controllers. The controller marked is
the FC 300 which is currently linked to the program displayed in the edit window. Naturally, you can also
mark and edit another FC 300.
Save a Temporary Program
Whenever you execute a program, it is loaded into
a temporary sector in the RAM, which is over-
written with each subsequent run. Here you can
permanently
Save the last temporary program
executed.
NB!:
It is recommended that the non-compiled
program file is also saved on the PC hard
drive since you can no longer edit the
compiled source file in the FC 300.
Click on
Save and enter a name in the sub-
sequent dialog field or confirm the file name
suggested. The program number will be assigned
automatically.
NB!:
When an attempt is made to save a new
program and a program is already active,
then the new program cannot be saved.
In this case, a dialog is presented that will allow a
Break to be sent to the currently active program.
The new program will then be saved.
Programs Save as
Click on
Save as and you can also assign the program number (0 to 90) yourself, in addition to the pro-
gram name.
Using this program number any program can also be started over the inputs, for example from a PLC. For
this all inputs are to be set accordingly with Controller
Include Sourcecode
When the check box is activated, the source code is protected in FC 300, in addition to directly executable
and compiled program files. This can be re-accessed when necessary and saved in a file on a PC.
When program source code is downloaded, then Include files within the source code are expanded and
downloaded with the source code. This allows a complete program, rather than only a partial program, to be
stored on the controller.
Click on
Save as and enter a name in the subsequent dialog field or confirm the file name. The suggested
filename contains the date and time to be safe from overwriting actual files in case of uploading.
62
__ PC Software Interface __
Parameters
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Global.

Advertisement

loading