33-5* I/O Configuration
There is one parameter per input and output. One
function assigned to each input and output via this
parameter.
Digital Input Functions
Digital input function
No function
Home switch 'no'
Home switch 'nc'
Negative end switch 'no'
Negative end switch 'nc'
Positive end switch 'no'
Positive end switch 'nc'
Error clear 'no'
Error clear 'nc'
Break program exe 'no'
Break program exe 'nc'
Continue program exe 'no'
Continue program exe 'nc'
Start program exe 'no'
Start program exe 'nc'
Program select
X57 = all
*) X59/7,8 only if par. 33-60 IOMODE is set to [0].
You can program all digital inputs 1 – 10 (12) to
these functions:
No function [0]: No reaction on signals from
the input_n.
Home switch no [1]: Defines digital input_n of
MCO 305 as home switch. Behavior after
reaching see HOME_TYPE.
Home switch nc [2]: Defines digital input_n
as home switch inverse. Behavior after
reaching, see HOME_TYPE.
Negative end switch no [3]: Defines digital
input_n as the negative end switch.
Negative end switch nc [4]: Defines digital
input_n as the negative end switch inverse.
Positive end switch no [5]: Defines digital
input_n as the positive limit switch.
Positive end switch nc [6]: Defines digital
input_n as the positive limit switch inverse.
default setting
206
__ Parameter Reference __
Select
Terminal
[0]
X57, X59/7,8*
[1]
X57, X59/7,8*
[2]
X57, X59/7,8*
[3]
X57, X59/7,8*
[4]
X57, X59/7,8*
[5]
X57, X59/7,8*
[6]
X57, X59/7,8*
[7]
X57, X59/7,8*
[8]
X57, X59/7,8*
[9]
X57, X59/7,8*
[10]
X57, X59/7,8*
[11]
X57, X59/7,8*
[12]
X57, X59/7,8*
[13]
X57, X59/7,8*
[14]
X57, X59/7,8*
[15]
X57, X59/7,8*
[ ]
value for use in communication via serial communication port
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Error clear no [7]: Defines digital input_n to
be used to clear an error.
Error clear nc [8]: Defines digital input_n to
be used to clear an error.
Break program exe no [9]: Defines digital
input_n to be used to react and abort a program
immediately, when activated. Such a program
can be continued with CONTINUE.
Break program exe nc [10]: Defines digital
input_n to be used to react and abort a program
immediately, when activated. Such a program
can be continued with CONTINUE.
Continue program exe no [11]: Defines
digital input_n to be used to continue aborted
programs.
Continue program exe nc [12]: Defines
digital input_n to be used to continue aborted
programs.
Start program exe no [13]: Defines digital
input_n to be used to define type of program
start.
If the input_n is set to [13], the Autostart pro-
gram is executed at first and the program waits
until input_n will be active. This is then evalua-
ted relevant to the program selection in order to
determine the number of the program to be run.
If no input for the program start is set, the pro-
gram with auto identification will be started.
Start program exe nc [14]: Defines digital
input_n to be used to define the type of
program start. If the input_n is set to [14], the
Autostart program is executed at first and the
program waits until input_n will be active. This
is then evaluated relevant to the program selec-
tion in order to determine the number of the
program to be run.
If no input for the program start is set, the pro-
gram with auto identification will be started.
Program select [15]: Defines digital input_n
to be used for a program selection. If input_n is
set to [15] then this parameter indicates the
input number starting at which the inputs for
the Program Selection are used. This includes all
numbers up to I_FUNCTION_14.