Download Print this page

Danfoss MCO 305 Design Manual page 221

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Troubleshooting
Warnings and Error Messages
All messages are shown in the LCP display of the FC 300 in short and in the APOSS software in plain text.
You can find brief information on the error messages in the table or detailed information in the following
section.
The tables contain the messages in numerical order. Letters following a % sign represent variables which
can be used in plain text at the corresponding locations.
Error
Error text
no.
103
Illegal axis num.
105
Error not reset
106
Home not done
107
Home vel. zero
108
Position error
109
Index not found
110
Unknown cmm.
111
SW end limit
112
Unknown param.
113
FC not enabled
114
Too many loops
115
Par. save failed
116
Param. memory
117
Progr. Memory
118
Reset by CPU
119
User abort
125
HW end limit
Description
Axes not in system.
Error not cleared.
Failed to move to HOME position.
Home was executed with Home Velocity set to zero.
Position error.
Index pulse (encoder) not found.
Unknown command.
Software end limit activated.
Illegal parameter number.
FC 300 is not ready but the PID controller is active.
Too many nested loops.
Parameters save failed.
Parameters in memory are corrupted.
Programs in memory are corrupted.
Reset by CPU.
User abort.
HW end limit activated.
®
MG.33.L4.02 – VLT