Delete all Programs
Click on Delete all if you want to delete all the programs in the FC 300. Make sure beforehand that you have
saved the programs on the PC or in the archive for safety reasons.
Controller > Parameters
The parameters in the Controller menu are divided
into two groups: the global parameters and the
axis parameters. Please see for more details,
parameter values, and the default settings the
chapter Parameter Reference.
Or simply press [F1] when the mouse cursor is in
one of the input fields and you get information
about the corresponding parameter.
Global and Axis Parameters
The global parameters include the input/output functions and the standard parameters which are grouped in
33-5* and 33-8*.
The axis parameters are always valid for all the programs belonging to one controller.
Mark the FC 300 you wish to edit in the dialog field. You can change each pre-set value individually. Click on
OK to load the changes in the FC 300.
With Reset
Parameter in the Controller menu can reset all the default settings; however in doing so all
parameters, including the axis parameters, are reset to default settings set in the factory.
There are two possibilities to set or change the parameters:
Set or Change Axis Parameters Online
Click on Controller
Parameters
or change in the subsequent dialog field. Also select the type in the field Parameters:
Slave Encoder
Master Encoder
Home
Inputs/Outputs (including Limit Handling)
PID-Controller
Synchronization
Velocity
You can change each parameter and re-load it in the FC 300 by clicking on OK. But you can also
immediately select another FC 300, change the parameters and then load all the changes into the FC 300
simultaneously with OK.
How to Change the Parameters of a Configuration File
Beside the possibility to change online the parameters, you can change all parameter settings of a saved
configurations file, too. For this case open the
index cards.
NB!:
These changes only relate to the CNF-file, but not to the parameter in the controller. To accept the
changed settings of the CNF-file into the controller, you have to load the CNF-file into the
controller: Controller
64
__ PC Software Interface __
Axis and mark the controller the parameters of which you want to view
par. group 32-0*
par. group 32-3*
par. group 33-0*
par. group 33-4* and 33-5*
par. group 32-6*
par. group 33-1*
par. group 32-8*
CAM Editor and change the parameter in the corresponding
Parameter
Restore from file.
®
MG.33.L4.02 – VLT