Download Print this page

Danfoss MCO 305 Design Manual page 209

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Brake control no [5]: Defines digital output_n
for brake. If an output is defined for the brake,
this remains active even when the program is
terminated with ESC.
The output is activated (24 V) in the case of an
abort or option error if par. 33-83 ERRCOND is
set to [1] or [3].
NB!:
The brake output must always be reset by
an OUT command in the program.
Example
ON ERROR GOSUB err_handle
// p. 33-66 O4 is set to [6]
SET ERRCOND 1
// Main program loop
SUBPROG err_handle
WAITI 1
ERRCLR
OUT 4 1
RETURN
Brake control nc [6]: Defines digital output_n
for brake. If an output is defined for the brake,
this remains active even when the program is
terminated with ESC.
The output is activated (0 V) in the case of an
abort or option error if par. 33-83 ERRCOND is
set to [1] or [3].
NB!:
The brake output must always be re-set
by an OUT command in the program.
33-63 Terminal X59/1 Digital Output
O_FUNCTION_1
No function
Function
Defines function of digital output 1 of MCO 305.
NOTE: This parameter is only visible when par. 33-
60 IOMODE = 1, i.e. output 1 is not used in
standard mode.
33-64 Terminal X59/2 Digital Output
O_FUNCTION_2
No function
Function
Defines function of digital output 2 of MCO 305.
NOTE: This parameter is only visible when par. 33-
60 = 1, i.e. output 2 is not used in standard mode.
default setting
__ Parameter Reference __
[0]
[0]
[ ]
value for use in communication via serial communication port
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
33-65 Terminal X59/3 Digital Output
O_FUNCTION_3
No function
Function
Defines function of digital output 3 of MCO 305.
33-66 Terminal X59/4 Digital Output
O_FUNCTION_4
No function
Function
Defines function of digital output 4 of MCO 305.
33-67 Terminal X59/5 Digital Output
O_FUNCTION_5
No function
Function
Defines function of digital output 5 of MCO 305.
33-68 Terminal X59/6 Digital Output
O_FUNCTION_6
No function
Function
Defines function of digital output 6 of MCO 305.
33-69 Terminal X59/7 Digital Output
O_FUNCTION_7
No function
Function
Defines function of digital output 7 of MCO 305.
33-70 Terminal X59/8 Digital Output
O_FUNCTION_8
No function
Function
Defines function of digital output 8 of MCO 305.
[0]
[0]
[0]
[0]
[0]
[0]
209