MCO 305 Design Guide
APOSS Software Messages
The APOSS software messages are arranged in
alphabetical order. Letters following a % sign
represent variables which can be used in plain text
at the corresponding locations.
Error text
Compilation error(s): program not saved!
Connection to %d already exists [%s] - change to
new Window
Connector %d pin %d is not valid in line %d
column %d
Controller is executing a program or command!
Error in array part of file.
Error in axis parameter part of file.
Error in global parameter part of file.
Lost connection to #%d!
Timeout: no reply from FC
Compilation error(s): program not saved!
A file is always compiled first and then saved. If
you want to save the program, for example in the
menu Controller
Save program and a syntax
error is found during compilation this message will
be displayed.
Start the
Syntax Check in the menu
Development , correct the syntax error and then
save the program.
Connection to . . . already exists . . .
Connection to %d already exists [%s] -
change to Window?
When opening a new window, or when trying to
connect a window with a controller that is already
linked to a window.
Yes: The controller is disconnected from the old
window and linked to the new window.
No:
The controller stays connected to the old
window. The new window is not linked to a
controller.
Connector pin is not valid
Connector %d pin %d is not valid in line %d
column %d
An illegal combination or a pin number which
cannot be set is used with the OUT command.
226
__ Troubleshooting __
Controller is executing a program or
command!
When the controller is executing a command or
program it is not available for additional
commands. You have to Break the new command
and re-start it once the previous command has
been completely executed.
Error in array part of file
When re-saving a configuration (e.g. with
Controller
computer recognizes that the data in the array
area is formatted incorrectly.
In order to be able to save a file, the following con-
ditions must be fulfilled:
Error in axis parameter part of file
When re-saving a configuration (e.g. with
from file ) the computer recognizes that the data in
the area of the axis parameters is formatted incor-
rectly. The parameter number and the sequence be
correct and numbering must be continuous.
In order to be able to save a file, the following con-
ditions must be fulfilled:
– Identical software versions, that provides same
– same configuration (e.g. same number of axes).
Error in global parameter part of file.
When re-saving a configuration (e.g. with
Restore from file ) the computer recognizes that the
data in the area of the global parameters is
formatted incorrectly. In order to be able to save a
file, the following conditions must be fulfilled:
– Identical software versions, that provides same
– same configuration (e.g. same number of axes).
Lost connection to ...
If the FC 300 is turned off or the plug is pulled, etc.
the window is disconnected from the FC 300 and
the lost connection is registered.
Timeout: no reply from FC
The FC 300 does not answer; check the connection.
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Parameters
Identical software versions,
same configuration (e.g. same number of axes),
in the case that arrays have already been input-
ted, these must match the ones that are to be
saved in terms of type and size.
number and order of the parameters,
number and order of the parameters,
Restore from file ) the
Restore