MCO 305 Design Guide
Development Menu
This menu provides functions to run, break,
continue, or to run the programs step-by-step for
debugging. The debug mode and the possibility to
change the variables during program execution
make programming easier.
However, before you begin it is always necessary to
select a controller or the FC 300.
Several helpful functions can be found in the
Command List. First of all, this lists a general over-
view of all APOSS commands, which can be
inserted to the edit window immediately. Secondly,
you can work here with the teach-in programming.
In offline mode, all functions which require access
to the drive can not be used. Most of the
Development menu items are disabled. APOSS will
use the drive connection that MCT 10 has already
established.
Execute [F5]
The program that is opened and displayed in the editor will be started.
In doing so the program is compiled and loaded into the FC 300. At the same time the program is loaded
into the temporary sector of the RAM; this is overwritten with each subsequent execute command. Thus,
when programming you have a quick and uncomplicated process to test the programs.
NB!:
However, it is neither possible to move a compiled program back to the computer, nor to edit the
source file on the PC again. Thus, in general, you should also save all programs on the hard drive
of the computer.
Break [Esc] and Break all
Click on Development
is possible that active motion processes could be ended prematurely.
NB!:
Braking is done with the maximum deceleration permitted.
If the program run in several controllers use Development
Continue Program
Click on Development
motion processes which were interrupted will be completed.
If a program with an error message was aborted, you can
have removed the error and/or erased the error message.
Messages -> Log file
This can be used to start the logging of messages to a file. Note that Stop logging will be enabled if logging
has been started.
__ PC Software Interface __
Break or press [Esc] in order to immediately abort the program. When doing so, it
Continue, in order to continue a program which was just aborted. In doing so any
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
Break all, to abort the programs running.
Continue it again with this function once you
57