Download Print this page

Danfoss MCO 305 Design Manual page 60

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Syntax Check [F4]
The program will be aborted as soon as a faulty command is found. The line number and an error descrip-
tion are outputted to the communications window. The cursor is automatically placed at the exact position
of the syntax error and the program stops at this point.
The Syntax Check produces a debug file in addition to checking the syntax. This file will be called "temp.ad$".
Convert (VLT5000 -> MCO 305)
This converter checks your previous programs,
gives a summery of the required changes, and
adds comments where changes have to be done.
Note: It does not change your program automati-
cally, see sample with LINKGPAR command.
Command List [F12]
The Command List offers all commands with their
syntax, which you can simply Insert into your
program. It is also possible to program your con-
troller with teach-in programming.
You can find detailed information on all commands
in this dialog field. Simply click on Help or press [F1]
and you get information to the marked command.
In operation mode offline it is not possible to exe-
cute any of the commands directly or to move the
drive to position.
Enter the position for the axis in the field. The pre-
view shows you the exact syntax of the command.
Now you can select from three alternatives which
you can mix randomly to program the FC 300.
NB!:
In general, the values entered during programming are not tested whether they are within the
permissible range. Due to the multitude of possible applications and various motor sizes this is not
possible nor is it desirable.
Insert or Execute now
Move the cursor in the edit window to the position where you want to insert one or more new commands,
click on Development
Command List and select the necessary command in the dialog field, e.g. POSA,
complement the value or a comment and click on
Or click on
Execute now and test this command before inserting it in your program.
NB!:
Enabled drives start up.
60
__ PC Software Interface __
Insert.
®