Download Print this page

Danfoss MCO 305 Design Manual page 207

Hide thumbs Also See for MCO 305:

Advertisement

MCO 305 Design Guide
Example
If I_FUNCTION_3_15 and I_FUNCTION_7_13,
then upon activation of input 7 the inputs 3, 4,
5, and 6 will be evaluated binary and the result
will be used as a program number.
Input
Level
3
low
4
high
5
high
6
low
=> program to be started:
Thus it is possible to choose between a maxi-
mum of 90 programs, identified with the
numerals 0 to 89.
NB!:
The values are not automatically reset if a
new input is defined. The user has to take
care of it. That means if I_FUNCTION_1 is
set to [1] (i.e. input 1 is the reference switch) and
the user sets I_FUNCTION_3 to [1] (i.e. input 3 is
reference switch) then two inputs are defined as
reference switches. The software always takes the
first one and the second one is ignored.
33-50 Terminal X57/1 Digital Input
I_FUNCTION_1
No function
Function
Defines function of digital input 1 of MCO 305.
33-51 Terminal X57/2 Digital Input
I_FUNCTION_2
No function
Function
Defines function of digital input 2 of MCO 305.
33-52 Terminal X57/3 Digital Input
I_FUNCTION_3
No function
Function
Defines function of digital input 3 of MCO 305.
default setting
__ Parameter Reference __
Binary value
0
2
0
6
[0]
[0]
[0]
[ ]
value for use in communication via serial communication port
®
MG.33.L4.02 – VLT
is a registered Danfoss trademark
33-53 Terminal X57/4 Digital Input
I_FUNCTION_4
No function
Function
Defines function of digital input 4 of MCO 305.
33-54 Terminal X57/5 Digital Input
I_FUNCTION_5
No function
Function
Defines function of digital input 5 of MCO 305.
33-55 Terminal X57/6 Digital Input
I_FUNCTION_6
No function
Function
Defines function of digital input 6 of MCO 305.
33-56 Terminal X57/7 Digital Input
I_FUNCTION_7
No function
Function
Defines function of digital input 7 of MCO 305.
33-57 Terminal X57/8 Digital Input
I_FUNCTION_8
No function
Function
Defines function of digital input 8 of MCO 305.
33-58 Terminal X57/9 Digital Input
I_FUNCTION_9
No function
Function
Defines function of digital input 9 of MCO 305.
[0]
[0]
[0]
[0]
[0]
[0]
207