NOTE:
Setup has two options, EZ (simplified) and Standard. Click on the View menu at the top of
the Setup screen, and select Standard view.
From the LoggerNet toolbar, click Main > Setup and configure the Network Map as described in
the following steps:
1. Select Add Root > IPPort.
2. Select PakBusPort
3. Add a data logger to the PakBusPort.
4. Select the IPPort in the Network Map. Enter the CR300-CELL IP address and port number.
The IP address and port number are input in the Internet IP Address field separated by a
colon. Preceding zeros are not entered in the Internet IP Address (for example,
070.218.074.247 is entered as 70.218.74.247). The default port number is 6785.
5. For PakBus data loggers, leave the default settings for the PakBusPort. PakBus Port Always
Open should not be checked. If used, enter the TCP Password.
8. Cellular communications option
39