Table 17-1: CR300 series terminal commands
Command
E
Compile errors
F
Settings names
H
Terminal emulator menu
I
Calibration data
J
Download file dump
L
Peripheral bus read
M
Memory check
N
File system information
O
Data table sizes
P
Serial talk through
REBOOT Program recompile
SDI12
SDI12 talk through
T
Terminal master
W
Comms Watch (Sniff)
PCAP
Wireshark PCAP file capture Campbell Scientific engineering tool
Description
Lists compile errors for the current program
download attempt.
Lists settings
Lists main menu.
Lists gains and offsets resulting from internal
calibration of analog measurement circuitry.
Sends text of current program including comments.
Campbell Scientific engineering tool
Lists memory-test results
Lists files in CR300 series memory.
Lists technical data concerning data-table sizes.
Issue commands from keyboard that are passed
through the logger serial port to the connected
device. Similar in concept to SDI12 Talk Through. No
timeout when connected via PakBus.
Typing "REBOOT" rapidly will recompile the CR300
series program immediately after the last letter, "T", is
entered. Table memory is retained. NOTE: When
typing REBOOT, characters are not echoed (printed
on terminal screen).
Issue commands from keyboard that are passed
through the CR300 series SDI-12 port to the
connected device. Similar in concept to Serial Talk
Through. See also
SDI-12 transparent mode
Communicate through the terminal mode of a
remote CR300 series by way of another CR300 series.
See also
Terminal master
Enables monitoring of CR300 series communication
traffic. No timeout when connected via PakBus.
Use
(p. 130)
(p. 132).