Normal Tsw Operation; Tsw Problem Indications And Solutions; Tsw Board Led Locations - IBM TotalStorage SAN256N Director 2045-N16 Installation And Maintenance Manual

Table of Contents

Advertisement

Fault LED
Pwr OK LED
Figure 43. TSW Board LED Locations

Normal TSW operation

During normal operation, the TSW Status LEDs provide the following information:
• The PWR OK LED is green, indicating that DC power to the module is within
tolerances and the module is not in a power on reset condition.
• The ONLINE LED is green, indicating that the TSW is active and logged into the fabric.
• The HEARTBEAT LED is flashing yellow, indicating that the module is functioning
correctly.
• The FAULT LED is not lit.

TSW problem indications and solutions

The following is a list of possible TSW problem indications, descriptions of the problems,
a probable cause, and an action to take.
Table 10. TSW problem indications, solution 1
PWR OK LED is not lit
Problem Summary
Probable Cause
108
SAN256N Director 2045-N16
TSW Board
Heartbeat LED
Online LED
Hardware diagnostics have failed.
The board may not be seated properly, or it may be faulty.