San Volume Controller 2145-Cg8 Or 2145-Cf8 Fan Locations And Connectors - IBM SAN Volume Controller 2145-CG8 Hardware Maintenance Manual

System storage san volume controller series
Hide thumbs Also See for SAN Volume Controller 2145-CG8:
Table of Contents

Advertisement

|
6
|
|
Figure 238. SAN Volume Controller 2145-CG8 or 2145-CF8 fan locations and connectors
|
1 Fan 1
|
2 Fan 2
|
3 Fan 3
|
4 Fan 4
|
5 Fan 5
|
6 Fan 6
|
7 Fan tabs
|
8 Fan connector on the system board
|
9 Fan connector
|
10 Side view of fan showing air-flow indicator
|
|
The node has six fan positions that are numbered right to left. The LED near the connector of the
failing fan assembly is lit, unless you remove the power cable.
|
4. Grasp the orange fan tabs on both ends of the existing fan and pull it up out of the node. If you are
|
|
removing fans 3 or 4, lift up the clear tab on the DIMM air baffle first.
Figure 239 on page 241 shows a fan being removed from the node.
|
|
240
IBM SAN Volume Controller Hardware Maintenance Guide
7
5
4
3
2
1
10
8
9