Concepts
MSR Overview
cdma2000: 1 kHz
1xEV-DO: 1 kHz

Channel Spacing

Carriers are placed based on corresponding channel spacing when they are
configured by the carrier config preset. Default channel spacings are listed
below.
E-UTRA (LTE): Channel BW
UTRA FDD (W-CDMA): 5 MHz
GSM/EDGE: 600 kHz
cdma2000: 1.25 MHz
1xEV-DO: 1.25 MHz
Channel spacing can be adjusted using channel spacing delta parameters.

MSR Test Configurations

In the standard, it defines many test configurations to verify the Multi-RAT
capability and performance. The table below is a summary, for details, see the
standard documentation 3GPP TS 37.141.
Table 3-8
MSR Test Configuration
Section in
TC
standard
4.8.1
TC1a/N
TC1a
4.8.1
TC1b
4.8.2
TC2
/NTC2
4.8.3
TC3a/N
TC3a
4.8.3
TC3b
4.8.4
TC4a/N
TC4a
4.8.4
TC4b/N
TC4b
4.8.4
TC4c/N
TC4c
4.8.4
TC4d
Keysight N9083A & W9083A Measurement Guide
BC
W-CDMA/HSPA
(UTRA FDD)
1, 2
X
3
1, 2, 3
1, 2
X
3
2
X
2
2
X
2
X
TD-SCDMA
LTE FDD
(UTRA TDD)
(E-UTRA FDD)
X
X
X
X
X
X
LTE TDD
GSM
(E-UTRA TDD)
X
X
X
X
X
X