Danfoss VLT AQUA Instruction Manual page 164

High power
Hide thumbs Also See for VLT AQUA:
Table of Contents

Advertisement

5 How to program the adjustable frequency
drive
5.3.12 13-** Smart Logic
Par.
Parameter description
No. #
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
5
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action
5.3.13 14-** Special Functions
Par.
Parameter description
No. #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
14-04
PWM Random
14-1* Mains On/Off
14-10
Line Failure
14-11
Line Voltage at Line Fault
14-12
Function at Mains Imbalance
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Cont, Proportional Gain
14-31
Current Lim Contr, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimizing
14-40
VT Level
14-41
AEO Minimum Magnetization
14-42
Minimum AEO Frequency
14-43
Motor Cos-Phi
14-5* Environment
14-50
RFI 1
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-59
Actual Number of Inverter Units
14-6* Auto Derate
14-60
Function at Overtemperature
14-61
Function at Inverter Overload
14-62
Inv. Overload Derate Current
14-8* Options
14-80
Option Supplied by External 24VDC
5-58
Default value
null
null
null
[0] Do not reset SLC
null
null
ExpressionLimit
ExpressionLimit
null
null
null
null
null
null
null
Default value
null
null
[1] On
[0] Off
[0] No function
ExpressionLimit
[3] Derate
[10] Automatic reset x 10
10 s
[0] Normal operation
null
60 s
ExpressionLimit
[0] No action
0 N/A
100 %
0.020 s
27.0 ms
66 %
ExpressionLimit
10 Hz
ExpressionLimit
[1] On
[0] Auto
[1] Warning
[0] No Filter
ExpressionLimit
[1] Derate
[1] Derate
95 %
[0] No
®
MG.20.P3.22 - VLT
is a registered Danfoss trademark
VLT AQUA High Power Instruction Manual
4-set-up
Change dur-
Conver-
ing operation
sion index
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
All set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-3
1 set-up
TRUE
-3
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
TRUE
-
2 set-ups
FALSE
-
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
0
All set-ups
FALSE
0
All set-ups
FALSE
-3
All set-ups
FALSE
-4
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
1 set-up
FALSE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
1 set-up
FALSE
-
1 set-up
FALSE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
0
2 set-ups
FALSE
-
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
TimD
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents