CHAPTER 6
This chapter describes setting procedures of the QD73A1.
● After writing the contents of the new module, parameter settings, and auto refresh settings into the CPU module, reset
the CPU module and switch its status as STOP RUNSTOP RUN, or turn off and on the power supply to activate
the settings.
● After writing the contents of the switch settings, reset the CPU module or turn off and on the power supply to activate the
settings.
6.1
Adding a Module
(1) Addition procedure
Open the "New Module" window.
Project window
Module Type
Module
Selection
Module Name
Base No.
Mount
Mounted Slot No.
Position
Specify start XY
address
Title setting
Title
VARIOUS SETTINGS
[Intelligent Function Module]
Item
Set "QD70 Type Positioning Module".
Set the name of the module to mount.
Set the base unit where the module is mounted.
Set the slot No. where the module is mounted.
The start I/O number (hexadecimal) of the module is set, according to the mounted
slot No. Any start I/O number can be set.
Set any title.
CHAPTER 6 VARIOUS SETTINGS
Right-click
[New Module...]
Description
6
99