(2) Intelligent function module switch setting
Configure the setting on "Switch setting" in "PLC parameter".
Parameter
Item
b7
0
0
0
0
0
0
0
0
1
Switch 1
276
[PLC parameter]
Bit
b0
Positive voltage is output when the positioning address increases.
0
Negative voltage is output when the positioning address increases.
1
b3
b2
b1
Fixed to 0 (Empty)
0
0
0
When a value is set, the value is ignored.
b6
b5
b4
0
0
0
-14800 to 14800 (default value)
0
0
1
-3700 to 3700 [Selection 1]
0
1
0
-7400 to 7400 [Selection 2]
0
1
1
-11100 to 11100 [Selection 3]
1
0
0
-14800 to 14800 [Selection 4]
1
0
1
-37000 to 37000 [Selection 5]
1
1
0
-74000 to 74000 [Selection 6]
1
1
1
-111000 to 111000 [Selection 7]
0
0
0
-148000 to 148000 [Selection 8]
b9
b8
0
0
4
0
1
2
1
0
1
1
1
1/2
b11
b10
Fixed to 0 (Empty)
0
0
When a value is set, the value is ignored.
b12
0
Reverse direction (address decreasing)
1
Forward direction (address increasing)
b13
0
Near-point dog method
1
Count method
b15
b14
Fixed to 0 (Empty)
0
0
When a value is set, the value is ignored.
[I/O assignment]
Click the
Setting detail
Rotation direction setting
Accumulated pulse setting (unit: pulse)
Multiplication setting
OPR direction setting
OPR method setting
button.
Select "HEX.".
*1