Mitsubishi Electric MELSEC Q Series User Manual page 206

Positioning module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

(4) JOG start timing
• During deceleration after a JOG start signal was turned off, if the JOG start signal for the same direction is
turned on, JOG operation starts again accelerating its speed.
Forward JOG start signal
• During deceleration after a JOG start signal was turned off, if the JOG start signal for the opposite direction
is turned on, JOG operation starts in the opposite direction after the completion of deceleration.
Forward JOG start signal
Reverse JOG start signal
204
v
ON
OFF
(Y24)
ON
BUSY signal
OFF
(X14)
Executed by the QD73A1
v
ON
OFF
(Y24)
(Y25)
OFF
ON
BUSY signal
(X14)
OFF
Executed by the QD73A1
ON
BUSY signal (X14) turns off for 0.5ms when switching.
t
t