Mitsubishi Electric MELSEC Q Series User Manual page 96

Positioning module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

Item
Immediate stop
accumulated pulse
Cd.14
setting value (maximum
value)
94
Description
The difference between the reference value
(maximum value) and the judgment value
(immediate stop accumulated pulses
(maximum value)) is set.
The relation between this setting and the
judgment value is as follows.
[If "
Accumulated pulse setting value
Cd.17
selection" is set to 0]
Immediate stop accumulated pulses
(maximum value) = reference value
(maximum value) +
Immediate stop
Cd.14
accumulated pulse setting value (maximum
value)
[If "
Accumulated pulse setting value
Cd.17
selection" is set to 1]
Immediate stop accumulated pulses
(maximum value) = reference value
(maximum value) + (
Immediate stop
Cd.14
accumulated pulse setting value (maximum
value) - 1000) × reference value (maximum
value)  1000
For details on the accumulated pulse error
detection function, refer to the following.
Page 223, Section 11.9
Setting range
• If "
Accumulated
Cd.17
pulse setting value
selection" is set to 0:
1 to 148000 pulse
• If "
Accumulated
Cd.17
pulse setting value
selection" is set to 1:
1000 to 50000
-3
(× 10
: Last three digits
are the value after the
decimal point.)
Buffer
Default
memory
value
address
(decimal)
402
0
403