Buzzer Control (Pr.990); Pu Contrast Adjustment (Pr.991) - Mitsubishi Electric FR-E700EX Instruction Manual

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Setting from the parameter unit and operation panel

4.21.4 Buzzer control (Pr.990)

You can make the buzzer "beep" when you press the key of the parameter unit (FR-PU07).
Parameter
number
990
PU buzzer control
The above parameter can be set when Pr.160 Extended function display selection = "0". (Refer to page 182)
The above parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr.77 Parameter
write selection.
REMARKS
 When with buzzer is set, the buzzer sounds if a drive unit fault occurs.

4.21.5 PU contrast adjustment (Pr.991)

Contrast adjustment of the LCD of the parameter unit (FR-PU07) can be performed.
Decreasing the setting value makes the contrast lighter.
Parameter
number
991
PU contrast adjustment
The above parameter is displayed as simple mode parameter only when the parameter unit FR-PU07 is connected.
The above parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr.77 Parameter
write selection.
260
Name
Initial value
Name
Initial value
Setting range
0
1
1
Setting range
58
0 to 63
Description
Without buzzer
With buzzer
Description
0: Light
63: Dark