(2)
Using the setting dial like a potentiometer to set the speed
Operation example
Changing the speed from 0r/min to 1800r/min during operation
Operation
1. Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Press
to choose the parameter setting mode.
4.
Turn
until
5.
Press
to read the currently set value.
"
"(initial value) appears.
6.
Turn
to change it to the set value "
7.
Press
to set.
8. Mode/monitor check
Press
twice to choose the monitor/speed
monitor.
9.
Press
to start the drive unit.
10.
Turn
until "
The flickering speed is the set speed.
You need not press
REMARKS
If the display changes from flickering "1800" to "0", the setting of Pr.161 Speed setting/key lock operation selection may not be "1".
Independently of whether the drive unit is running or at a stop, the speed can be set by merely turning the dial.
When the speed is changed, it will be stored in EEPROM as the set speed after 10s.
Setting from the parameter unit and operation panel
(Pr.161) appears.
".
" appears.
.
Display
PU indicator is ON.
PRM indicator is ON.
(The parameter number read previously appears.)
Flicker... Parameter setting complete!!
The frequency flickers for about 5s.
4
257