Mitsubishi Electric FR-E700EX Instruction Manual page 148

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Function assignment of external terminal and control
Setting
Signal
Positive
Negative
logic
logic
64
164
Y64
68
168
EV
90
190
Y90
91
191
Y91
93
193
Y93
95
195
Y95
96
196
REM
98
198
LF
99
199
ALM

9999

Note that when the speed setting is varied using an analog signal or
ON and OFF depending on that varying speed and the timing of the varying speed due to acceleration/deceleration time setting.
(The output will not alternate ON and OFF when the acceleration/deceleration time setting is "0s".)
REMARKS
 The same function may be set to more than one terminal.
 When the function is executed, the terminal conducts at the setting of any of "0 to 99", and does not conduct at the setting of
any of "100 to 199".
NOTE
 Changing the terminal assignment using Pr.190 to Pr.192 (output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
 Do not assign signals which repeat frequent ON/OFF to terminal A, B, C. Otherwise, the life of the relay contact
decreases.
146
Function
During retry
Output during retry processing.
The signal is output while the main circuit power
24V external power
supply is off and the 24V power is supplied externally.
supply operation
This signal is available when FR-E7DS is mounted.
Output when any of the control circuit capacitor, main
Life alarm
circuit capacitor and inrush current limit circuit or the
cooling fan approaches the end of its service life.
Fault output 3
Output when a fault occurs due to the internal circuit
failure of the drive unit wiring mistake.
(power-off signal)
Average current value and maintenance timer value
Current average value
are output as pulses.
The signal can not be set in Pr.192 A,B,C terminal
monitor signal
function selection.
Output when Pr.503 rises to or above the Pr.504
Maintenance timer signal
setting.
Output to the terminal when a value is set to the
Remote output
parameter.
Output when an alarm (communication error warning)
Alarm output
occurs.
Output when the drive unit's protective function is
Fault output
activated to stop the output (at fault occurrence).
The signal output is stopped when the fault is reset.
No function
Operation

of the operation panel, the output of the SU (up to speed) signal may alternate
Refer
Related
to
parameter
page
Pr.65 to Pr.69
164


Pr.255 to
245
Pr.259

148
Pr.555 to
249
Pr.557
Pr.503, Pr.504
248
Pr.495, Pr.496
152
Pr.121
204

148

