Usb Communication (Pr. 547, Pr. 548) - Mitsubishi Electric FR-E700EX Instruction Manual

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Communication operation and setting

4.18.7 USB communication (Pr. 547, Pr. 548)

Drive unit setup can be easily performed using the FR Configurator by connecting the drive unit and personal computer
with a USB cable.
 A personal computer and drive unit can be easily connected with one USB cable.
Parameter
number
USB communication
547
station number
USB communication
548
check time interval
 Changed setting value is valid when powering on or resetting the drive unit.
USB communication specifications
Interface
Transmission speed
Wiring length
Connector
Power supply
 You can perform parameter setting and monitoring with the FR Configurator. Refer to the instruction manual of the FR
Configurator for details.
REMARKS
 USB cable available on the market
Name
USB cable
Parameters referred to
Pr. 551 PU mode operation command source selection
234
Name
Initial value
0
9999
Conforms to USB1.1
12Mbps
Maximum 5m
USB mini B connector (receptacle mini B type)
Self-power supply
USB connector
USB cable
<How to open the USB connector cover>
Pull the cover in the direction of arrow.
Model
MR-J3USBCBL3M
Cable length 3m
Setting range
0 to 31
Drive unit station number specification
USB communication is possible
0
Trips in the PU operation mode (E.USB)
Sets the interval of communication check time.
If a no-communication state persists for longer
0.1 to 999.8s
than the permissible time, the drive unit trips
(E.USB).
9999
No communication check
Then turn it upward.
Application/Specifications
Connector for amplifier
mini-B connector (5 pin)
Refer to page 195
Description
Connector for personal computer
A connector