Limiting The Rotation Speed; Maximum/Minimum Setting (Pr.1, Pr.2) - Mitsubishi Electric FR-E700EX Instruction Manual

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

4.7

Limiting the rotation speed

Purpose
To set upper limit and lower limit of
rotation speed
To perform operation by avoiding
mechanical resonance points
4.7.1

Maximum/minimum setting (Pr.1, Pr.2)

You can limit the motor speed.
Clamp the upper and lower limits of the rotation speed.
Parameter
Name
number
1
Maximum setting
2
Minimum setting

When a value exceeding 3000 r/min is set, the rotation speed will be limited at 3000 r/min.
Also, when an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000 r/
min)
Rotation speed
(r/min)
Pr.1
Pr.2
0
(4mA)
Clamped at the
minimum setting
REMARKS
 Because the speed is limited by the speed command, the upper limit value or a higher value may be displayed on the monitor.
(2)
Set minimum speed
 Use Pr.2 Minimum setting to set the minimum rotation speed.
 If the set speed is less than Pr.2, the rotation speed is clamped at Pr.2 (will not fall below Pr.2 ).
REMARKS
 When Pr.15 Jog speed setting is equal to or less than Pr.2, the Pr.15 setting has precedence over the Pr.2 setting.
 When torque limit is activated to decrease the rotation speed, the rotation speed may drop to Pr.2 or below.
 Because the speed is limited by the speed command, the lower limit value or a lower value may be displayed on the monitor.
NOTE
 Under position control, the lower limit setting is disabled.
Note that when Pr.2 is set to any value equal to or more than Pr.13 Starting speed, simply turning ON the start
signal will run the motor at the preset speed according to the set acceleration time even if the command speed
is not input.
Parameters referred to
Pr.13 Starting speed
Pr.15 Jog speed setting
Pr.125 Terminal 2 speed setting gain speed, Pr.126 Terminal 4 speed setting gain speed
Maximum/minimum setting
Speed jump
Initial value
3000r/min
0r/min
(1)
 Use Pr.1 Maximum setting to set the maximum rotation speed. If the
Clamped at the
maximum setting
value of the speed command entered is higher than the setting, the
rotation speed is clamped at the maximum speed.
 The speed command is also clamped at the operable speed range
of the selected motor.
If the motor's operable maximum speed < maximum setting, the
Speed setting value
speed does not increase to the maximum speed.
5, 10V
(20mA)
CAUTION
Refer to page 128
Refer to page 119

Limiting the rotation speed

Parameter to set
Pr.31 to Pr.36
Setting range
0 to 4800r/min
Upper limit of the rotation speed.
0 to 4800r/min
Lower limit of the rotation speed.
Set maximum speed
Refer to page 173
Refer to page
Pr.1, Pr.2
115
116
Description
4
115

Hide quick links:

Advertisement