4.15.4 Bias and gain of speed setting voltage (current)
(Pr.125, Pr.126, Pr.241, C2 (Pr.902) to C7 (Pr.905))
You can set the magnitude (slope) of the rotation speed as desired in relation to the speed setting signal (0 to 5V, 0 to
10V or 4 to 20mADC).
Set Pr.267 and voltage/current input switch to switch between 0 to 5VDC, 0 to 10VDC, 0 to 20mADC using terminal 4.
(Refer to page 168)
[Speed setting bias/gain parameter]
Parameter
number
Terminal 2 speed setting
125
gain speed
Terminal 4 speed setting
126
gain speed
Analog input display unit
241
, 
switchover
C2(902)
Terminal 2 speed setting bias
speed
, 
C3(902)
Terminal 2 speed setting bias
, 
C4(903)
Terminal 2 speed setting
gain
, 
C5(904)
Terminal 4 speed setting bias
speed
, 
C6(904)
Terminal 4 speed setting bias
, 
C7(905)
Terminal 4 speed setting
gain
, 

This parameter can be set when Pr.160 Extended function display selection = "0". (Refer to page 182)

The parameter number in parentheses is the one for use with parameter unit (FR-PU07).

This parameter allows its setting to be changed during operation in any operation mode even if "0" (initial value) is set in Pr.77 Parameter write selection.

When a value exceeding 3000 r/min is set, the rotation speed will be limited at 3000 r/min.
Also, when an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000 r/
min)
Speed setting by analog input (terminal 2, 4)
Initial
Name
value
3000r/min
3000r/min
0
0r/min
0%
100%
0r/min
20%
100%
Setting
range
0 to 4800r/min

Speed of terminal 2 input gain (maximum).
0 to 4800r/min
Speed of terminal 4 input gain (maximum).

Displayed in
0
%
Displayed in
1
V/mA
0 to 4800r/min

Speed on the bias side of terminal 2 input.
Converted % of the bias side voltage of
0 to 300%
terminal 2 input.
Converted % of the gain side voltage of
0 to 300%
terminal 2 input.
0 to 4800r/min

Speed on the bias side of terminal 4 input.
Converted % of the bias side current (voltage)
0 to 300%
of terminal 4 input.
Converted % of the gain side current (voltage)
0 to 300%
of terminal 4 input.
Description
Unit for analog input display.