Mitsubishi Electric FR-E700EX Instruction Manual page 165

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

(2)
How to calibrate the terminal FM when using the operation panel
Operation
1.
Confirmation of the operation status indicator
and operation mode indicator
2.
Press
to choose the parameter setting
mode.
3.
Turn
until
4.
Press
to display
5.
Turn
until
Set to C0 FM terminal calibration.
6.
Press
to enable setting.
7.
If the drive unit is at a stop, press the
key to start the drive unit.
8.
Turn
to adjust the indicator needle to the
desired position.
9.
Press
.
Setting is complete.
Turn
Press
Press
REMARKS
 Calibration can also be made for external operation. Set the speed in the External operation mode, and make calibration in the
above procedure.
 Calibration can be made even during operation.
 For operation from the parameter unit (FR-PU07), refer to the instruction manual of the parameter unit.
Parameters referred to
Pr.54 FM terminal function selection
Pr.55 Speed monitoring reference
Pr.56 Current monitoring reference
Monitor display and monitor output signal
appears.
.
appears.
Flicker...Parameter setting complete!!
to read another parameter.
to return to the
indication (step 4).
twice to show the next parameter (
Refer to page 155
Refer to page 161
Refer to page 161
Display
(When Pr.54 = 1)
PRM indicator is lit.
(The parameter number read previously appears.)
C0 to C7 setting
is enabled.
The monitor set to
Pr. 54 FM terminal function
selection is displayed.
Analog indicator
Hz
A
).
4
163