Parameter list
Function Parameter
Name
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Fault history clear
Pr.CH
Initial value change list
PM
PM parameter initialization
AUTO
Automatic parameter setting

When an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 12000 r/min, 3.7K: 8000 r/min)

The setting differs according to the drive unit capacity. (0.75K or lower / 1.5K or higher)

The setting differs according to the drive unit capacity. (0.75K or lower / 1.5K and 2.2K / 3.7K)

When an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 900 r/min, 3.7K: 600 r/min)

When an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 450 r/min, 3.7K: 300 r/min)

When an S-PM geared motor is used, the maximum setting value differs depending on the drive unit capacity. (0.2 to 2.2K: 1350 r/min, 3.7K: 900 r/min)

The setting differs according to the drive unit capacity. (0.1K: 3024, 3124 / 0.2K to 0.75K: 3024, 3124, 6004, 6104 / 1.5K to 3.7K: 6004, 6104)

The setting differs according to the drive unit capacity. (0.1K: 3024 / 0.2K to 0.75K: 3024, 6004 / 1.5K to 3.7K: 6004)

The setting differs according to the drive unit capacity. (0.75K or lower: rated current of MM-GKR motor (Refer to page 307.), 1.5K or higher: rated current of
S-PM geared motor (Refer to page 310.))
 The parameter number in parentheses is the one for use with the parameter unit (FR-PU07).
 The setting is applied after a drive unit reset or power-ON.
 Write is disabled in the communication mode (Network operation mode) from the PU connector.
 These parameters are communication parameters that are not cleared when parameter clear (all clear) is executed from RS-485 communication. (Refer to
page 204 for RS-485 communication).
 When a communication option is installed, parameter clear (lock release) during password lock (Pr.297  9999) can be performed only from the
communication option.
 A verification error may occur during parameter verification of the parameters copied using the parameter unit (FR-PU07). A verification error on the
manufacturer setting parameters will not affect the operation. Press the "0" key on the parameter unit and proceed with the operation. (Refer to the
Instruction Manual of the parameter unit.)
REMARKS
 The unit for parameter setting and its setting range can be changed from "r/min" to "Hz". Use Pr.144 to change the setting.
 With operation panel, the value up to 9999 can be set. With parameter unit (FR-PU07) or FR Configurator, up to the highest
value in the setting range can be set.
 A value exceeding 3000r/min can be also set, but the actual operation will be limited at 3000r/min, which is the upper speed
limit of the motor.
68
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0, 1
1
0
261
0, 1
1
0
261
0, 1
1
0
263
262
3024/6004
 
3024, 6004
1
73
*8

253
Customer
Parameter Remarks
Setting
Pr.CL
ALLC
Er.CL
Pr.CH
PM
AUTO
Motor/Control Mode Support Table
Instruction Code
S-PM
MM-GKR
Read Write Extended
Speed
Speed
position
FC
FC
F4
Parameter list
Parameter
Copy
Clear
All clear
4