Setting-Dial Potentiometer Mode/Key Lock Operation Selection (Pr.161) - Mitsubishi Electric FR-E700EX Instruction Manual

Sensorless servo drive unit, applied
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Setting from the parameter unit and operation panel

4.21.2 Setting-dial potentiometer mode/key lock operation selection (Pr.161)

The setting dial of the operation panel can be used for setting like a potentiometer.
The key operation of the operation panel can be disabled.
Parameter
number
Speed setting/key lock
161
operation selection
The above parameters can be set when Pr.160 Extended function display selection = ""(Refer to page 182)
(1) Using the setting dial to set the speed
Operation example
Operation
1. Screen at power-ON
The monitor display appears.
2.
Press
to choose the PU operation mode.
3.
Turn
to display the speed you want to set.
The speed flickers for about 5s
4.
While the value is flickering, press
speed.
(If you do not press
5s and the display then returns to " " (0r/ min). In that
case, go back to "operation step 3" and set the speed
again.)
The value flickers for about 3s and the display then
returns to " " (monitor display).
5. Start  acceleration  constant
speed
Press
to operation.
The speed value on the display increases in Pr.7
Acceleration time, and "
6.
To change the set speed, perform the steps 3 and 4. (Starting from the previously set speed)
7. Deceleration  Stop
Press
to stop the operation.
The speed value on the display decreases in Pr.8
Deceleration time, and the motor stops running with
" " (0r/min) displayed.
REMARKS
If
is not pressed within 5s after
256
Name
Initial value
Operate at 900r/min
to set the
, the value flickers for about
" (900r/min) appears.
is turned, the operation may not performed at the set speed.
Setting
range
0
1
0
10
11
PU indicator is ON.
Flicker... Speed setting complete!!
After 3s, the monitor display appears.
Description
Setting dial speed
setting mode
Setting dial
Key lock invalid
potentiometer
mode
Setting dial speed
setting mode
Setting dial
Key lock valid
potentiometer
mode
Display
STOP

Hide quick links:

Advertisement

Table of Contents
loading