4.16.2 Parameter write disable selection (Pr.77)

You can select whether write to various parameters can be performed or not. Use this function to prevent parameter
values from being rewritten by misoperation.
Parameter
Name
number
77
Parameter write selection
The above parameters can be set when Pr.160 Extended function display selection = "0". (Refer to page 182)
Pr.77 can always be set independently from the operation mode and operation status.
(1)
Write parameters only during stop (setting "0" initial value)
 Parameters can be written only during a stop in the PU operation mode.
 The shaded parameters in the parameter list (page 52) can always be written regardless of the operation mode and
operating status.
(2)
Inhibit parameter write (setting "1")
 Parameter write is not enabled.
(Read is enabled.)
 Parameter clear and all parameter clear cannot be
performed, either.
 The parameters given on the right can be written if Pr.77 =
"1".
(3)
Write parameters during operation (setting "2")
 Parameters can always be written.
 The following parameters cannot be written when the drive unit is running if Pr.77 = "2". Stop the drive unit when changing
their parameter settings.
Parameter
number
40
RUN key rotation direction selection
48
Second torque limit level
79
Operation mode selection
178 to 184
(Input terminal function selection)
190 to 192
(Output terminal function selection)
Command pulse multiplication numerator
420
(electronic gear numerator)
Command pulse multiplication denominator
421
(electronic gear denominator)
463
Position control rotation direction selection
Parameters referred to
Pr.79 Operation mode selection
Misoperation prevention and parameter setting restriction
Initial value
0
Name
Refer to page 186
Setting range
0
Write is enabled only during a stop.
1
Parameter can not be written.
Parameter write is enabled in any operation
2
mode regardless of operation status.
Parameter
number
22
Torque limit level
Reset selection/disconnected PU detection/
75
PU stop selection
77
Parameter write selection
79
Operation mode selection
160
Extended function display selection
296
Password lock level
297
Password lock/unlock
997
Fault initiation
Parameter
number
535
Position control terminal input selection
537
Roll feed mode selection
658
Wiring resistance
736
Electromagnetic brake interlock time
785
PM control torque boost
795
DC brake torque boost
800
Control method selection
998
PM parameter initialization
999
Automatic parameter setting