SENSe:SWEep:TINTerval

Syntax
SENSe:SWEep:TINTerval <interval>, (@<ch>)
This command defines the time period between samples in milliseconds on
models that have measurement controls. Programmed values can range from
1 to 32767.
SENSe:SWEep:TINTerval? (@<ch>)
Queries the time interval set.
Parameters
Item
<ch>
<interval>
Returned Query Format
<NR1>
The query command returns the time interval for each channel specified. The
returned value is the time period in milliseconds.
Examples
The following command specifies a time interval of 10 milliseconds between
measurement points on channel 1.
SENS:SWE:TINT 10, (@1)
The following query returns the measurement time interval for channel 2.
SENS:SWE:TINT? (@2)