Keysight U2722A Programmer's Reference Manual page 132

Usb modular source measure units
Hide thumbs Also See for U2722A:
Table of Contents

Advertisement

14
Error Messages
Table 14-2
Command errors (continued)
Error
Command errors (these errors set the Standard Event Status register bit #5)
–110
Command header error
An error was detected in the header.
–111
Header separator error
A character that was not a valid header separator was found in the command string.
–112
Program mnemonic too long
The header contains more than 12 characters.
–113
Undefined header
A command was received that is not valid. You may have misspelled the command or it may not be a valid
command. If you are using the short form of the command, remember that it may contain up to four letters.
–114
Header suffix out of range
The value of the numeric suffix is not valid.
–120
Numeric data error
Generic numeric data error.
–121
Invalid character in number
An invalid character was found in the number specified for a parameter value.
Example: *ESE #2
–123
Exponent too large
A numeric parameter was found where its exponent was larger than 32,000.
–124
Too many d igits
The mantissa of a numeric parameter contained more than 255 digits, excluding leading zeros.
–128
Numeric data not allowed
A numeric parameter was received but a character string was expected.
–130
Suffix error
Generic suffix error.
–131
Invalid suffix
A suffix was incorrectly specified for a numeric parameter.
–134
Suffix too long
The suffix contains more than 12 characters.
–138
Suffix not allowed
A suffix is not supported for this command.
132
Keysight U2722A/U2723A Programmer's Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U2723a