Broadcast

7.3.5
Description: This command is used to Enable/Disable listening broadcast packets on
PDS-220Fx.
Effect: Immediate
Command
Arguments
Broadcast
Broadcast
= 1
Broadcast
= 0
Example:

SystemTimeout (ms)

7.3.6
Description: This command queries or sets the system timeout value.
If the SystemTimeout is greater than zero, and the PDS-220Fx does not receive any
packets from any client for longer than the SystemTimeout period, the PDS-220Fx will
reboot itself.
Effect: Immediate
Command
SystemTimeout
SystemTimeout
Example:
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
Description
Queries the Broadcast settings.
Sets Broadcast = 1.
The system is able to receive broadcast packets.
Sets Broadcast = 0.
The system will ignore broadcast packets.
Arguments
Description
Queries the SystemTimeout settings.
Sets the SystemTimeout. (Unit : ms)
= nnnnn
Default factory setting is 300000 ms (= 300 seconds =
5 minutes ), min. value is 30000 ms (= 30 seconds)
63