Chapter 2 Troubleshooting
2.3 Error Code FIP
Step
Check the REGI. CLUTCH operation
Execute the Diag Digital Output [071-006] to check the
7
operation of the REGI. CLUTCH.
Is the REGI. CLUTCH operating normally?
Check the operation of the DRIVE ASSY MAIN
Execute the Diag Digital Output [071-001] to check the
8
rotation of the DRIVE ASSY MAIN.
Is it working properly?
Check and Action
2-56
Yes
Go to Step 8.
Go to FIP2.8
Replace the
PWBA MCU.
Go to FIP2.12
(REP 18.2)
No