Step
Checking after resetting the PWBA MCU.
21
Reseat the PWBA MCU.
Is the image printed correctly?
Checking after resetting the PWBA ESS.
22
Reseat the PWBA ESS.
Is the image printed correctly?
Checking after resetting the Transfer Unit.
23
Reseat the Transfer Unit.
Is the image printed correctly?
Checking after replacing the Transfer Unit.
24
Replace the Transfer Unit.
Is the image printed correctly?
Checking after replacing the Drum Cartridge.
25
Replace the Drum Cartridge.
Is the image printed correctly?
Checking after resetting the HVPS.
26
Reseat the HVPS.
Is the image printed correctly?
Checking after replacing the ROS ASSY.
27
Replace the ROS ASSY. (REP 2.1)
Is the image printed correctly?
Chapter 3 Image Quality Troubleshooting
Check and Action
3-13
3.2 Image Quality Troubleshooting
Yes
End of work.
End of work.
End of work.
End of work.
End of work.
End of work.
End of work.
No
Go to step 22.
Go to step 23.
Go to step 24.
Go to step 25.
Go to step 26.
Go to step 27.
Replace the
HVPS. (REP
18.3)