7.2 Options
Type
Name
Complementary Type
PG Interface
PG-B3
PG Speed
Controller Card
<2>
Line Driver PG
Interface
PG-X3
Expansion PLC Board
PLC Function
BC-620
<1> Only one optional communication card can be selected.
<2> To apply PG control, the PG speed control card must be selected.
<3> Documentation is being prepared.

◆ Panel Housed Type

Type
Momentary
Uninterruptible Power
Power Loss
Supply (UPS) Unit
Compensation
Continuation of
Backup Cooling Fan
Operation
Measures for Cold
Space Heater
Regions
Panel Door Open Interlock
<1> Under development
<2> Documentation is being prepared.

◆ Separate Installation Type

Type
Name
USB Copy Unit
Maintenance
JVOP-181
Power Cell
Lifter for Replacing
Replacement
Power Cells
Inrush Current
Installation
Suppression
Circuit
<1>
<1> Under development
<2> Documentation is being prepared.
180
For control modes requiring a PG encoder for motor feedback.
• Phase A, B, and Z pulse (3-phase) inputs (complementary type)
• Max. input frequency: 50 kHz
• Pulse monitor output: Open collector, +24 V, max. current 30 mA
• Power supply output for PG: +12 V, max. current 200 mA
For control modes requiring a PG encoder for motor feedback.
• Phase A, B, and Z pulse (differential pulse) inputs (RS-422)
• Max. input frequency: 300 kHz
• Pulse monitor output: RS-422
• Power supply output for PG: +5 V or +12 V, max. current 200 mA
Supplements PLC functions required to customize the drive.
• Program memory capacity: Equivalent to 8,000 steps
• Execution speed: 1,000 steps/1 ms
• Language: Ladder language, textual language
Name
UPS is installed inside the panel and backs up a control power supply
when momentary power losses occur.
This option is required to implement measures against momentary
power loss (for the speed search function or KEB function)
Automatically enables continued operation of the drive in case of one
<1>
of the cooling fans fails to operate. (N + 1 backup system)
Suppresses dew condensation inside the panel by adding a space
heater circuit.
Note: This option does not always prevent dew
condensation. Use the drive in an environment
with no dew condensation.
Detects opening of the panel door by adding a limit switch.
Medium-voltage power shutdown command is output on detecting
opening.
Enables the copying and transfer of parameters between drives
using (one-touch) simple operations. This unit can also be used as
a conversion connector between the communication port (RJ-45)
of an drive and a USB port of a PC running DriveWizard Plus MV.
This option comprises a copy unit with USB interface, an RJ-45
cable and a USB cable.
Facilitates power cell replacement.
Note: A maintenance space of at least 2000 mm must
be secured in front of the panel in order to
replace Power Cells with a lifter.
Suppresses the inrush current on turning the drive power on by
adding a circuit (inrush suppression circuit panel)
Function
Table 7.2 Options
Function
Table 7.3 Options
Function
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
Reference Manual
Complementary Type PG
Installation Manual
(TOBPC73060036)
Motor PG Feedback
Line Driver Interface
Installation Manual
(TOBPC73060037)
<3>
Reference Manual
<2>
Reference
Manual
<2>
Refer to
Periodic
Inspection &
Maintenance on page
159.
<2>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents