4.3 The Drive and Programming Modes
Simplified Setup Using the Setup Group
■
In the Setup Group, the drive lists the 32 parameters registered as User Parameters. It provides a simplified way to get the
application running right away by showing only the most important parameters. Refer to
example.
Note: For details on the parameters of the setup mode, refer to Chapter 1 Parameter List of the FSDrive-MV1000 Parameter Guide.
Key operations in the setup mode are shown in the following figure.
In this example, the Setup Group is accessed to change b1-01 from 1 to 0. This changes the source of the frequency
reference from the control circuit terminals to the digital operator.
Figure 4.7
- MODE -
DRV
Rdy
FREF (OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
LSEQ
U1-03= 0.0A
LREF
JOG
FWD
FWD/REV
Frequency reference
appears when
powered up
<1> To edit a parameter set value, go to the right steps.
To confirm the parameter list displayed in the Setup Group, go to the steps below.
<2> To go back to the initial screen, press
To edit another parameter in the Setup Group, press
86
- MODE -
PRG
Quick Setting
HELP
FWD
DATA
- SETUP -
PRG
Application Sel
A1-06= 0
∗0∗
General
Home
FWD
Parameter Display
- SETUP -
PRG
Control Method
∗2∗
A1-02= 2
Open Loop Vector
Home
FWD
<1>
- SETUP -
PRG
Ref Source 1
∗1∗
b1-01= 1
Analog Input
Home
FWD
- SETUP -
PRG
Run Source 1
∗1∗
b1-02= 1
Digital Inputs
Home
FWD
- SETUP -
PRG
StallP Decel Sel
∗1∗
L3-04= 1
General Purpose
Home
FWD
.
or
Figure 4.7 Setup Group Example
Rdy
DATA
Rdy
DATA
Rdy
DATA
Entry Accepted
Rdy
DATA
Rdy
DATA
.
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
Figure 4.7
as an operation
- SETUP -
PRG
Rdy
Ref Source 1
b1-01=
1
∗1∗
Analog Input
"1"
←
→
FWD
Control Circuit
Terminal
- SETUP -
PRG
Rdy
Ref Source 1
b1-01=
0
∗1∗
Operator
"1"
←
→
FWD
Digital Operator
<2>