7.2

Options

The list of options is shown below. To order an option, contact your Yaskawa representatives or the nearest Yaskawa
sales office.
• Selecting options: For details on procurement, see the Yaskawa catalogs.
• Installing and wiring options: Refer to the manual for each option.

◆ Built-in Type

All built-in type options are connected to the connectors on the controller board.
Type
Name
Analog Input
AI-A3
Speed (Frequency)
Reference Card
Digital Input
DI-A3
DeviceNet Interface
SI-N3
PROFIBUS-DP
Interface
SI-P3
Communications
Card
<1>
CP-215 Interface
215IF
Ethernet (CP-218)
Interface
218IF
Analog Monitor
AO-A3
Monitor Card
Digital Output
DO-A3
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
Table 7.1 Options
Function
Enables high-precision and high-resolution analog speed reference
setting.
• Input signal level: -10 to +10 Vdc (20 kΩ), 4 to 20 mA (500 Ω)
• Input channels: 3 channels (DIP switch for input voltage/input
current selection)
• Input resolution: Input voltage 13 bit signed (1/8192)
Input current 1/6554
Enables 16-bit digital speed reference setting.
• Input signal: 16 bit binary, 4 digit BCD + sign signal + set signal
• Input voltage: +24 V (isolated)
• Input current: 8 mA
User-set: 8 bit, 12 bit, 16 bit
Used for running or stopping the drive, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through DeviceNet communication with the host controller.
Used for running or stopping the drive, setting or referencing
parameters, and monitoring output frequency, output current, or similar
items through PROFIBUS-DP communication with the host controller.
Used for running or stopping the drive, setting or viewing parameters,
and monitoring output frequency, output current, etc. through CP-215
communication with the host controller.
The CP-215 communication system is a high-speed, real-time, N:N
network with shared memory, handling both cyclic and message
transmissions. An optional expansion PLC board (BC-620) is needed
to use it and should be procured at the same time.
Used for running or stopping the drive, setting or viewing parameters,
and monitoring output frequency, output current, etc. through CP-218
communication with the host controller.
The CP-218 communication system is a type of Ethernet that supports
communication with the MEMOBUS protocol, non-protocol, or
MELSEC protocol. An optional expansion PLC board (BC-620) is
needed to use it and should be procured at the same time.
Outputs analog signal for monitoring drive output state (output freq.,
output current etc.).
• Output resolution: 11 bit signed (1/2048)
• Output voltage: -10 to +10 Vdc (non-isolated)
• Terminals: 2 analog outputs
Outputs isolated type digital signal for monitoring drive run state
(alarm signal, zero speed detection, etc.)
• Terminals: 6 photocoupler outputs (48 V, 50 mA or less)
2 relay contact outputs (250 Vac 1 A or less, 30 Vdc 1 A
or less)
7.2 Options
Reference Manual
Analog Input
Installation Manual
(TOBPC73060038)
Digital Input
Installation Manual
(TOBPC73060039)
DeviceNet Installation
Manual (TOBPC73060043)
DeviceNet Technical
Manual (SIEPC73060043)
PROFIBUS-DP
Installation Manual
(TOBPC73060042)
PROFIBUS-DP Technical
Manual (SIEPC73060042)
<3>
<3>
Analog Monitor
Installation Manual
(TOBPC73060040)
Digital Output
Installation Manual
(TOBPC73060041)
179
7