5.5 Alarm Detection
Digital Operator Display
dnE
Cause
"Drive Enable" is set for a sequence input
(H1-
= 6A) and that signal has been
switched off.
Digital Operator Display
EF
Cause
Sequence error
Digital Operator Display
EF0
Cause
An external fault was received from the PLC
with F6-03 = 3 (causing the drive to continue
running when an external fault occurs).
There is a problem with the PLC program.
Digital Operator Display
EF1
EF2
EF3
EF4
EF5
EF6
EF7
EF8
EF9
EF10
EF11
EF12
EF13
EF14
EF15
EF16
132
Drive Disabled
Possible Solutions
⇒Check the operation sequence.
Forward/Reverse Run Command Input Error
Both forward run and reverse run closed simultaneously for over 0.5 s.
Possible Solutions
⇒Check the forward and reverse command sequence and correct the
problem.
Note: When minor fault EF detected, motor ramps to stop.
Option Card External Fault
An external fault condition is present.
Possible Solutions
⇒Remove the cause of the external fault.
⇒Remove the external fault input from the PLC.
⇒Check the PLC program and correct problems.
External Fault (input terminal)
External fault input at sequence input terminal 1
External Fault (input terminal)
External fault input at sequence input terminal 2
External Fault (input terminal)
External fault input at sequence input terminal 3
External Fault (input terminal)
External fault input at sequence input terminal 4
External Fault (input terminal)
External fault input at sequence input terminal 5
External Fault (input terminal)
External fault input at sequence input terminal 6
External Fault (input terminal)
External fault input at sequence input terminal 7
External Fault (input terminal)
External fault input at sequence input terminal 8
External Fault (input terminal)
External fault input at sequence input terminal 9
External Fault (input terminal)
External fault input at sequence input terminal 10
External Fault (input terminal)
External fault input at sequence input terminal 11
External Fault (input terminal)
External fault input at sequence input terminal 12
External Fault (input terminal)
External fault input at sequence input terminal 13
External Fault (input terminal)
External fault input at sequence input terminal 14
External Fault (input terminal)
External fault input at sequence input terminal 15
External Fault (input terminal)
External fault input at sequence input terminal 16
Minor Fault Name
Minor Fault Name
Minor Fault Name
Minor Fault Name
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
Minor Fault
Output
H2-
=10
Yes
Minor Fault
Output
H2-
=10
Yes
Minor Fault
Output
H2-
=10
Yes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents