7: HMI F
UNCTION

Monitoring the FC6A Series MICROSmart

Monitoring Device Values
You can check device values on the FC6A Series MICROSmart. The HMI module features two types of device monitors.
Going to device monitor mode from the standard screen
Device values can be checked but not modified.
Running Device Monitor on the system menu
Device values can be checked and modified.
Device values can be monitored regardless of the user program operating status (run/stop). This section describes the device
monitor mode when the user program is running.
If you press the
(left) and
1.
monitor mode and the device values can be monitored (Device values cannot be modified). Continue to press the
(right) buttons to change the device type.
R
0123456789
0010 ,
R
0123456789
0020 ,
R
0123456789
0030 ,
R
0123456789
The device type changes in the order below.
I
Q
T
TC
I, Q, T, C, M, and R are bit devices.
TC, TP, CC, CP, and D are word devices.
Note: I1000 or greater, Q1000 or greater, and non-retentive data registers are not displayed in the Device Monitor.
Press the
(up) and
2.
7-32
(right) buttons on the standard screen, the FC6A Series MICROSmart switches to the device
2015/DEC/01/TUE
TP
C
CC
CP
D
Data Register
(down) buttons to change the device number.
Shows the on/off state of the inputs (I).
Inverted inputs are on state.
FC6A S
MICROS
ERIES
Running
13:30:40
M
R
Internal Relay
U
'
M
FC9Y-B1722
MART
SER
S
ANUAL
0000 ,
I
01234567
0010 ,
I
01234567
0020 ,
I
01234567
0030 ,
I
01234567
(left) and