To suspend the forced I/O, click the Start/Suspend Force button
5.
The forced inputs or outputs remain designated until the forced I/O designation is released.
To release the forced I/O designation, click the Force Release button
6.
Now input I0 works as a normal input.
Note: Make sure that all the forced inputs and outputs are released when the test using the forced I/O function is finished. Select Delete All from
the right click menu in the Forced I/O List dialog box to release all the forced inputs and outputs at once.
FC6A S
MICROS
U
ERIES
MART
.
.
'
M
FC9Y-B1722
SER
S
ANUAL
5: F
S
UNCTIONS AND
ETTINGS
Even though I0 is designated,
forced I/O is suspended and
actual input status is read to the
FC6A Series MICROSmart.
Input I0 is released from the
forced I/O designation. Even
when forced I/O is enabled, actual
input status is read to the FC6A
Series MICROSmart.