4.4.5.19

Changing the Time Request Interval

Softkey
4.110
Selection / Editor
Editor
In the central area the currently active value is
displayed.
Changing the Time Request Interval
Description
1. Press softkey 'Time REQ INTV'.
2. Enter a new interval or change interval se-
lectively.
3. Press 'ENT' to confirm.
The value is now effective.
Possible values:
From 0 (single) up to 255 minutes within a step
width of 1 minute.
When the time quality of a station falls below a
certain threshold, the time acquisition protocol
is started automatically. Using this protocol the
station tries to improve its time quality. The in-
tervals between these attempts can be pro-
grammed via the function 'Time REQ INTV'.
The protocol runs until the time quality reaches
a sufficient value.
If the interval is set to '0', the time request
is switched to 'single', so that the operator
is able to make a single time request. If the
softkey 'Time REQ' (see
sect. 4.4.5.15 Switching the Time Synchro-
nization On or Off) was already enabled,
the user has to disable it and then enable it
again, in order to perform the single time
request.
Operating Manual 6175.4760.02 – 01