M3SR Series 4100
3.7.2.27
Changing the PEP (Peak Envelope Power) to Average Power Factor
Softkey
3.164
Changing the PEP (Peak Envelope Power) to Average Power Factor
Softkey Type
Editor
Description
1. Press 'PEP/PAvg' softkey.
2. Change to desired value.
Possible values:
0 dB to 12 dB
With this setting, the automatic level control
(ALC) of the power amplifier can be adjusted
to the characteristic of external modems to
achieve highly linear signal amplification. It af-
fects the J2D and B7D Tx direction only.
Operating Manual 6175.4760.02 – 01