R&S M3SR 4100 Series Operating Manual page 200

Software defined radios
Table of Contents

Advertisement

M3SR Series 4100
Softkey
3.84
Description
Open a listbox and use the
knob to select the DCD
mode.
Press 'ENT' to confirm.
Open an editor and select the attenuation applied on the
DSC module (option) audio connector (audio in signal).
Select the attenuation with the knob or with the numeric
keypad.
This softkey is enabled only if the DSC module (op-
tion) is present in the radio.
Default: 0.0 dB
Open an editor and select the attenuation applied on the
DSC module (option) audio connector (audio out signal).
Select the attenuation with the knob or with the numeric
keypad.
This softkey is enabled only if the DSC module (op-
tion) is present in the radio.
Default: 0.0 dB
Menu Radio MTC 3/7 (3003)
Default: HF DETECTION
Operating Manual 6175.4760.02 – 01
Possible Values
The DCD mode controls the
behavior of the RS232 DCD
pin.
HF DETECTION
The Data Carrier Detected
(DCD) is active as long as the
receiver receives an RF sig-
nal.
DATA WRAPPING
The DCD is active as long as
the serial interface has valid
output data.
-100 to +100
(equivalent to -10.0 dB to
+10.0 dB in steps of 0.1 dB)
-100 to +100
(equivalent to -10.0 dB to
+10.0 dB in steps of 0.1 dB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr4100gMr4100eMr4100xMr4100g-b

Table of Contents