M3SR Series 4100
3.7.2.1
Storing Current Settings
Softkey
3.134
Softkey Type
Editor
Storing Current Settings
Description
1. Press 'Channel Store' softkey.
2. Enter desired channel.
3. Press 'ENT' key to confirm.
If the 'Channel Store' softkey is pressed, it
shows the frequency and modulation of the
channel.
Channel not used (e.g.)
Channel used (e.g.)
By means of softkey 'Channel Store' the oper-
ator can store the current equipment setting in
a particular channel. The effective channel is
displayed in the menu header, e.g. CH: 101.
If the entered channel number is within the
permitted entry range, the editor window will
be closed.
Possible values:
Channels 1 to 400, pre-configured with the
R&S RNMS3000 software tool.
With the R&S RNMS software tool you can
configure these channels as modifiable or
not modifiable by the user.
If a channel has already been stored via R&S
RMNS3000 and was configured as modifiable,
the storing will overwrite it. If the channel was
configured as not modifiable via R&S
RMNS3000, it is not possible to store it or
overwrite it from the MMI.
Channel store/recall is only available on Pre-
set Page 0. Other Fixed Frequency Preset
Pages consist only of one channel.
Operating Manual 6175.4760.02 – 01